Loading...
15 All Faults
16 Fire Alarm 0 = Any Area,
1 - 16 = Areas 1 - 16
17 Fire Reset
18 AWAY Armed 0 = All Areas
1 - 16 = Areas 1 - 16
19 STAY Armed
20 Reset *1 0 = Any Area
1 - 16 = Area number
21 Follow Zone Event (Alarm and
tamper)
Zone Number 1 - 64
22 RF Keyfob button 3 (Garage Door) 0 = Any Area,
1 - 16 = Areas 1 - 16
23 RF Keyfob button 4 (light)
24 Chime Indication *1
25 Verfied Alarm
26 Unverfied Alarm
27 Technical Alarm
28 Bypassed Zone
29 Ready to Arm 0 = All Areas 1 - 16 = Areas 1 - 16
30 Walktest
Output
Mode
0 Continuous output
1 Pulse
2 Inverted
Output
Time
000 -
999
0 - 999 seconds
*1 Output Timer is fix. (1 sec)
DX3010 Output Programming
This section is optional programming.
Module
Address
DX3010 module 1 (Output 5 - 12) 150
DX3010 module 2 (Output 13 - 20) 151
Table 9.2: DX3010 Address Settings
DX3010 1 Output Programming
Address 0542 - 0605
See The Value Ranges of Output Programming Options