Installation
Compress 5800i AW – 6721858460 (2023/06)
14
Fig. 14 Wooden parts, metal brackets and straps
Make sure the text “IDU” on the wooden parts is facing upwards. Then
the cut-outs will fit over the feet on the indoor unit.
Fig. 15 Wooden part
Place the wooden parts and metal brackets under the indoor unit and
attach the straps.
Fig. 16 Brackets and straps attached to indoor unit
NOTICE
Risk of damage!
The metal brackets and the wooden parts are not firmly attached to the
appliance, there is thus a risk that it can slide while carrying.
The bracket and wooden part are only intended for transporting the
appliance vertically, as there is a risk of loosing the stability due to high
center of gravity.
Be at least two persons while carrying the appliance.
Do not use the brackets and wooden parts for horizontal transport,
e.g staircase.
4.3 Remove the front
Fig. 17 Remove the front
4.4 Installation checklist
Each installation is unique. The following checklist provides a general
description of how the installation should be performed.
1. Install the fill valve.
2. Install the non-return valve (if the cooling mode is to be used).
3. Install the leakage drain hoses.
4. Connect heat pump to the indoor unit.
5. Connect the indoor unit to the heating system.
6. Install particle filter and magnetite separator (magnetite separator is
only optional for new building with only under-floor heating system).
7. Connect the tap water to the indoor unit and the pressure-relief valve.
8. Mount the outside temperature sensor and any room controller.
9. Connect the CAN-BUS cable to the heat pump and the indoor unit.
10.Install any accessories.
0010048275-001