Electrical connection
23
Compress 5800i AW – 6721858460 (2023/06)
The external inputs are connected either to a circuit breaker for manual
activation or a control device with a potential free relay output.
6.9 Establishing the power supply connection
6.9.1 Main supply
Observe local rules and regulations when choosing the correct cross-
section of the cables and cable types, however the cross-section
specified here must be adhered to.
Table 10 Cable area and cable type
Fig. 30 Wire striping mains feed connection
6.9.2 Cable feeds in the indoor unit
1. Remove the electrical box cover.
2. Route the cables from the cable inlets to the electric box:
– Feed the connecting cables over the cable glands on the back
through the corrugated hoses. Use an extension string. See figure
31 for the correct order of the hoses.
– Fix the cables with cable ties at the fixing points (Figure 32 [7]
and [9]). Avoid crossing the cables.
– The cable routing must be done in such a way that the cables don’t
touch hot surfaces like pipes or the booster heater.
3. Feed the cables into the electric box.
4. Connect the cables according to the chapters 6.9.3 – 6.9.4.
5. Reattach the cover of the electric box.
Fig. 31 Cable inlets to the indoor unit
[1] I1-I4: External inputs
T1: Temperature sensor outdoor
MD1: Condensation sensor (accessory for cooling mode)
CAN-BUS cables
EMS-BUS cable for accessory
[2] 230V~1N, output from PK2, cooling season
[3] 230V~1N, output to DHW circulation pump PW2
[4] 400V~3N, input to indoor unit (booster heater)
[5] Fixing points on sheet metal plate for fixing the cables with cable
ties
[6] Electric box
Fig. 32 Cable feeds to electric box
[1] CAN-BUS cables
[2] I1-I4: External inputs
T1: Temperature sensor outdoor
Option 1: Option 2:
9kW (3kW only)
Function Indoor unit Indoor unit
Cable type
Terminals
allow use of
fine-stranded
or solid core
wire
According to local
rules and
regulations
According to
local rules and
regulations
Cable
diameter
5 x 2,5 mm
2
3 x 2,5 mm
2
Fuse and
maximum
external load
1)
1) External load to outputs
3x16A: max.
135W
3x20A - 25A:
max. 500W
1x16A: max.
135W
1x20A - 25A:
max. 500W
≤10 mm
≤120 mm
0010048737-001
3
2
4
6
1
0010049964-001
5
4
7
6
3
0010049965-001
2
1
8
5