Hydraulic connections
19
Compress 5800i AW – 6721858460 (2023/06)
Fig. 22 Indoor unit connections to the heating system
[1] Heating system return line
[2] Heating system flow line
[*] It is mandatory to install a non-return valve to use the cooling
mode (see required accessories chapter in 2.8.1).
Fig. 23 Indoor unit backside
[1] Drain hose
5.5 Connect the indoor unit to the tap water
WARNING
Risk of system damage
If the function of the pressure-relief valve cannot be guaranteed,
excessive pressure occurs in the system.
WARNING – Make sure that the pressure relief valve outlet is never
plugged or shut off.
WARNING
Risk of scalding!
If the installation requires DHW temperatures >65 °C (i.e for solar
thermal systems, combination with wood boilers or similar), a
temperature mixing device must be installed.
The pressure relief valve, the non-return valve for incoming cold water,
the fill valve and the DHW mixer must be installed in the tap water circuit
(not included in the scope of delivery).
Install the pressure relief valve and cold water valve (VW3) with a
non-return valve for tap DHW.
Pull the leakage drain water line from the pressure relief valve to a
frost protected outlet.
Connect optional pump for domestic hot tap water (accessory).
Connect domestic hot water out [1].
Connect cold water in [2].
The domestic tap water system must be protected from pollution at
the installation
T
T
*
1
0010038735-005
2
SC1
1
0010049184-001