Compress 5800i AW – 6721858460 (2023/06)
8
2.6 Roof panel
Fig. 6 Product overview top view
[1] Flow to heating system
[2] DHW outlet connection
[3] Cold water inlet connection
[4] Heat transfer medium out (to the heat pump)
[5] Heat transfer medium in (from heat pump)
[6] Label for pipe connections
[7] Return from heating system
[8] DHW circulation connection (accessory)
2.7 Regulations
Follow the directives and regulations given below:
Local provisions and regulations of the electricity supplier and
corresponding special rules
National building regulations
EN 50160 (voltage properties in power grids for public distribution)
EN 12828 (heating systems in buildings - Design and installation of
water-based heating systems)
EN 1717 (Protection of potable water against pollution in potable
water installations)
EN 378 (Refrigerating systems and heat pumps - Safety and
environmental requirements)
EN60335-2-40 (Particular requirements for electrical heat pumps,
air-conditioners and dehumidifiers)
PED, 2014/68/EU (Pressure equipment directive)
2.8 Accessories
2.8.1 Required system components
The following components are not included in the standard delivery but
are required for the initial startup and operation of the system.
Heating system:
Automatic air vent valve [VL1]
Magnetite filter/separator (not necessary if the system only consists
of newly installed underfloor heating)
Equipment for filling of heating and DHW system
Non-return valve if the cooling mode is to be used.
2 3
4
5
7
1
0010038584-004
8
6

Table of Contents

Related product manuals