Operation
Compress Hybrid 7000i AW – 6721833054 (2020/09)
10
3.2.8 Renaming a time program or heating circuit
Standard designations are preassigned to the time programs and
heating circuits.
Open the menu for renaming a time program
Open the main menu.
▶Open the Heating/Cooling > Time program > Heating circuit 1...4 >
Rename time program menu.
The cursor flashes to indicate the start position for data input.
Open the menu for renaming a heating circuit (only available if 2 or
more heating circuits are installed)
Open the main menu.
▶Open Heating/Cooling > Time program > Heating circuit 1 >
Rename heating circuit menu (or other heating circuit).
The cursor flashes to indicate the start position for data input.
Entering/adding characters
Open menu for renaming a time program or heating circuit.
Turn the selector to position the cursor in the required location.
Press the selector to activate the input field (to the right of the cursor).
Select character and confirm.
The selected character is entered (added). The input field for the next
character in the text is activated.
Press the d key to complete the input.
Deleting characters/resetting name
To delete a character:
Open menu for renaming a time program or heating circuit.
Place the cursor behind the character to be deleted by turning the
selector.
Press the selector to activate the input field.
Select the character <C and confirm.
The character to the left of the input field is deleted.
To reset the name:
Delete all characters.
The standard designation is entered again automatically.
3.2.9 DHW settings
In hybrid systems, DHW is only supplied by the external booster heater,
which means that all DHW settings at the control unit of the indoor unit
have no effect and must therefore be deactivated.
To do this, select Operating mode off (Chapter 3.3.2, tab. 6).
All other DHW settings apply for DHW systems with cylinder.
When the thermal disinfection function is activated, the DHW cylinder is
heated to the corresponding temperature set. The higher temperature
hot water can be used for thermal disinfection of the hot water system.
Observe regional and local requirements and operating conditions
for the DHW circulation pump, including the water quality and
instructions of the heat source.
Select the operating mode for DHW heating
To activate the constant DHW heating:
Select and confirm Always on - DHW Eco+
Lowest DHW temperature mode that results in lowest energy
consumption.
-or-
Always on - DHW Eco.
Medium DHW temperature mode that results in medium energy
consumption.
-or-
Always on - DHW comfort
Highest temperature mode that results in higher energy consumption
and may also lead to a higher sound level from the system.
The DHW temperatures for each mode is set by the installer.
0010008233-001
0010008199-001
0010008200-001
0010008204-001