3.3.5 Settings for other systems or devices
If other specific systems or devices are installed in the system, additional
menu items will be available. Depending on which system or device is
being used and the associated assemblies or components, various
settings can be made. Observe the additional information on the settings
and functions in the technical documentation for the relevant system or
device.
Settings for a swimming pool
Menu: Pool
Table 14 Settings for pool heating
Settings for smart grid
This menu is only available if a smart grid system is installed.
Table 15 Settings in the smart grid data menu
Settings for a hybrid system
This menu is only available if a hybrid system is installed. The system
then has two heat sources; a heat pump and a separate conventional gas
or oil burner.
Depending on the current situation and heat requirements, either the
heat pump or the conventional heat source offers a more favourable
energy/price ratio. Based on this ratio the controller decides which heat
source to operate.
The energy/price ratio must be adjusted regularly to the actual price
ratios.
The ratio is calculated with these formulas:
Ratio for gas = (cost of electricity per kWh / cost of gas per kWh) X
heat factor of boiler
Ratio for oil= (cost of electricity per kWh / cost of oil per liter) X heat
factor of boiler
Example:
Cost of electricity = 24 ct/kWh
Cost of gas = 8 ct/kWh
Heat factor of boiler = 0,902
Energy/price ratio = (24/8)X 0,902 = 2,7
The heat factor of the boiler (boiler efficiency) must be adapted to the
installed appliance ( manual of the appliance).
Menu: Hybrid system
Table 16 Settings for a hybrid system
Setting a time program for an auxiliary heater
This menu is only available if an auxiliary heater is installed in the heating
system.
Menu: time prog. for add. heater
Table 17 Settings of time program for auxiliary heater
Settings for a photovoltaic system
Make the photovoltaic (PV) specific settings in this menu. Select if the
available energy should be used for Heating or DHW.
If photovoltaic energy is available and a buffer cylinder is installed with all
heating circuits mixed, the buffer cylinder will be heated to the heat
pump maximum temperature.
Menu: PV system
Table 18 Settings in the PV system data menu
Menu item Description
Switch on pool
heating
This setting enables the pool heating when it is
activated.
Pool
temperature
The water in the pool is heated to this temperature.
Allow add. heater
for pool
This setting allows the auxiliary heater to supply
heating for the pool if the heat pump cannot reach
the set temperature.
Menu item Control range: Function description
Heating The energy available in the smart grid is used for heating, if
the system is in heating mode.
[Selectable increase]: 0...5 °C
Set how much the room temperature may be increased.
[Forced increase]: 2...5 °C
Set how much the room temperature is forced to increase.
DHW The energy available in the smart grid is used for DHW.
[Selectable increase]: [Yes] | [No]
If enabled the DHW is heated to the temperature set for
DHW operating mode [Always on - DHW comfort].
No heating is done if the holiday program is active.
Menu item Description
Energy price
ratio
Enter the calculated energy/price ratio.
Menu item Description
Start add. heater
time pr.
With this setting activated the auxiliary heater will
only be allowed to operate in the [on] phases.
My time program Set the time program for the auxiliary heater.
Reset time prog. Reset the time program to the default settings.
Time prog min
outd temp
Below this outdoor temperature the time program is
off and the auxiliary heater can operate at any time.
[off] means that the time program runs regardless of
the outdoor temperature.
Menu item Control range: Function description
Heating increase The energy available in the PV system is used for heating, if
the system is in heating mode.
Set how much the room temperature may be increased
0...5 °C.
DHW increase The energy available in the PV system is used for DHW.
Yes | No
If enabled the DHW is heated to the temperature set for
DHW operating mode. No heating is done if the holiday
program is active.
Cooling setback
mode
The energy available in the PV system is used for cooling.
Yes | No
If enabled the room temperature is decreased to the
temperature set for cooling operating mode. No cooling is
done if the holiday program is active.
Only cool with PV Cooling mode is activated only if energy is available in the
PV system.
Yes | No
If enabled the room temperature is decreased to the
temperature set for cooling operating mode. No cooling is
done if the holiday program is active.