9.6.2 Checking and, if required, adjusting the gas/air ratio
Switch off the appliance.
Remove the front cover.
Remove the burner cover.
Fig. 39 Removing the burner cover
After converting a gas type, roughly adjust the gas type on the scale
of the gas adjustment nozzle.
L = n.a.
H = natural gas
LPG = liquid propane
Fig. 40 Adjusting the gas/air ratio
[1] Adjustable nozzle
Operate the appliance.
Remove the bung from the flue gas test port.
Push the flue gas probe centrally into the flue gas test port.
Seal the test point.
Fig. 41 Flue gas test port
To ensure heat transfer: open the radiator valves.
Set the chimney sweep mode and start up the device at maximum
rated output ( Chapter 9.7.1, page 40).
Measure the CO
2
or O
2
content.
▶Check the CO
2
or O
2
content at maximum rated output according to
Tab. and match if required.
To increase the CO
2
content, turn the adjustable nozzle to the left.
▶To reduce the CO
2
content, turn the adjustable nozzle to the right.
Table 25 CO
2
and O
2
contents
Measure the CO content.
The CO content must be < 250 ppm.
Set the minimum rated output.
Measure the CO
2
or O
2
content.
0010020558-003
1.
2.
Maximum rated
heat output
Minimum rated
heat output
Gas type CO
2
O
2
CO
2
O
2
Natural gas 9.5 % 4.0 % 8.6 % 5.5 %
Liquid gas (LPG) Propane 10.8 % 4.6 % 10.2 % 5.5 %
Liquid gas (LPG) Butane 11.9 3.2 11.2 5.0
0010040995-001