Technical information and reports
Condens 8300i W – 6721841531 (2022/10)
58
Table 30
13.2 Ionisation current
Table 31 Ionisation current
13.3 Sensor values
Table 32 Outside temperature sensor (for weather-compensated
controllers, accessory)
Table 33 Flow temperature sensor
13.4 Coding plug
Table 34 Coding plug
Max. permissible operating pressure (PMS), heating bar 2.5 2.5 2.5
Max. permissible operating pressure (PMS), domestic hot water bar 10 10 10
Permissible ambient temperature short time/long time °C 0 - 50/40 0 - 50/40 0 - 50/40
Heating water quantity l 5.2 5.2 5.2
Weight (without packaging) kg 50 50
Dimensions W × H × D mm 440 × 780 ×
365
440 × 780 ×
365
440 × 780 ×
365
Maximum installation attitude m 2000 2000 2000
GC8300iW 35/40 C
Unit Natural gas Propane Butane
If the burner is running at minimum rated output
Gas type OK Faulty
Natural gas ≥ 7 A< 7A
Liquid gas (LPG) ≥ 10 A< 10A
Temperature [°C ± 10 %] Resistance []
-20 2392
-16 2088
-12 1811
-8 1562
-4 1342
0 1149
4 984
8 842
12 720
16 616
20 528
24 454
Temperature [°C ± 10 %] Resistance []
0 35 975
5 28 538
10 22 763
15 18 284
20 14 772
25 12 000
30 9 786
35 8 054
40 6 652
45 5 523
50 4 607
55 3 856
60 3 243
65 2 744
70 2 332
75 1 990
80 1 703
85 1 464
90 1 261
95 1 093
100 949
Type Gas type Number
GC8300iW 35/40 C Natural gas 20456
GC8300iW 35/40 C Liquid gas (LPG) 20457