Troubleshooting
49
Condens 8300i W – 6721841531 (2022/10)
Variant with screws
In service menu 6t-5, set 1 DHW and check the motor.
In service menu 6t-5, set 2 Middle position.
▶Unplug the plug.
Remove the screws.
Pull on the motor gently and lift it up.
Remove the motor.
Fig. 69 Detaching the motor from the 3-way valve (variant with screws)
When suspending the motor, do not push against the ball head, as it will
be hard to pull it out again.
Lower the new motor from above and suspend it from the ball head.
Push the motor in and fasten it in place using 2 screws.
▶Connect the plug.
Fig. 70 Installing the motor in the 3-way valve (variant with screws)
9.21 Following inspection/maintenance
Re-tighten all the threaded connections that have been released.
Restart the device ( page 24).
Check tightness of all joints.
Check the gas/air ratio.
▶Fit the casing.
10 Troubleshooting
10.1 Operating and fault displays
10.1.1 General information
The Fault code specifies the cause of the fault.
The Fault category specifies the impact of a fault on the device
operation.
Fault category O (operating code)
Operating codes specifiy an operating condition in normal mode.
Fault category B (blocking faults)
Blocking faults result in the heating system being shut down temporarily.
The heating system restarts automatically as soon as the blocking fault is
removed.
Fault category V (locking faults)
Locking faults result in the heating system being shut down, and the
system can only be restarted after a reset.
The fault code of a locking fault flashes together with the H on the
display.
Check if a serious fault is present.
Switch the device off and back on again.
-or-
Press the keys and at the same time until the symbols H and
! disappear.
The device resumes operation. The flowtemperature appears on the
display.
If a fault persists after a reset:
Remedy the cause of the fault according to the details in the table
further down.
Fault category W (service displays)
Service displays indicate that a maintenance or repair has to be carried
out. The device is still in operation. If the service display has been caused
by a defect, under certain circumstances, it may continue running with
restricted functions.