Technical specifications and reports
CS3000 AWP – 6721852570 (2023/04)
76
Table 67 The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No
811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated
heat output ≤ 400 kW at specified reference conditions). Contains fluorinated greenhouse gases (GWP 675)
1. Entering/leaving water temperature user side 30/35 °C, Entering
external exchanger air temperature 7 °C (R.H. = 85%)
2. COP (EN 14511:2018) Heating performance coefficient. Ratio
between delivered heating capacity and power input in compliance
with EN 14511:2018. The overall power absorbed is calculated by
adding the power absorbed by the compressor + the power absorbed
by the fan - the percentage value of the fan to overcome external
pressure drop + the power absorbed by the pump - the percentage
value of the pump to overcome pressure drop outside + the power
absorbed by the auxiliary electrical circuit.
3. Entering/leaving water temperature user side 40/45 °C, Entering
external exchanger air temperature 7 °C (R.H. = 85%)
4. Entering/leaving water temperature user side 23/18 °C, Entering
external exchanger air temperature 35 °C
5. EER (EN 14511:2018) cooling performance coefficient. Ratio
between delivered cooling capacity and power input in compliance
with EN 14511:2018. The overall power absorbed is calculated by
adding the power absorbed by the compressor + the power absorbed
by the fan - the percentage value of the fan to overcome external
pressure drop + the power absorbed by the pump - the percentage
value of the pump to overcome pressure drop outside + the power
absorbed by the auxiliary electrical circuit
6. User side entering/leaving water temperature 12/7 °C, external
exchanger entering air 35°C
7. Seasonal Space Heating Energy Efficiency Class according to
Commission delegated Regulation (EU) No 811/2013. W = Water
outlet temperature (°C)
8. Data referred to unit operation with inverter frequency optimized for
this application
9. Data calculated according to the EN 14825:2016 Regulation
10.Seasonal energy efficiency in heating EN 14825:2018
11.Seasonal energy efficiency in cooling EN 14825:2018
16.2 Construction
Heating capacity (EN
14511:2018)
3 kW 24,3 27,1 31,4 48,6 54,0 62,0 73,4 84,0
COP (EN 14511:2018) 2 3,30 3,27 3,20 3,32 3,26 3,10 3,19 3,19
Cooling
Cooling capacity (EN
14511:2018)
6 kW 22,3 25,8 29,0 42,0 48,0 55,0 68,9 79,8
EER (EN 14511:2018) 5 3,022,842,802,692,632,643,092,81
SEER 9 4,63 4,64 4,63 4,00 3,99 4,01 4,14 4,04
ns,c 12 % 182 183 182 157 157 157 163 159
SEPR 10 6,12 6,1 6,09 5,64 5,61 5,47 6,14 5,81
Water flow-rate 6 l/s 1,06 1,23 1,39 2,01 2,29 2,63 3,22 3,81
User side exchanger
pressure drops
6 kPa 23 29 41 28 32 36 31,5 42,4
SIZE 16 19 24 31 36 41 53 59
SIZE AWP16 AWP19 AWP24 AWP31 AWP36 AWP41 AWP53 AWP59
Compressor
Type of compressors Rotary inverter Scroll Inverter
Refrigerant R32
No. of compressors Nr 1 2
Oil charge l 2.3 4.6 6
Refrigerant charge kg 7.9 14 17.5
No. of refrigerant circuits Nr 1
User side exchanger
Type of internal exchanger 1) PHE
No. of internal exchanger Nr 1
Water content l 2.44 5.17 7.8
External exchanger
Type of external exchanger 2) CCHY
No. of coils Nr 2
External Section Fans
Type of fans AX
No. of fans Nr 1 2 3
Type of motor Brushless DC
Standard airflow -
Standard mode
m
3
/h 11520 13500 13500 23040 27000 27000 34560 40500
Standard airflow - Super
silent mode
m
3
/h 5400 8280 8280 10800 16560 16560 24840 24840