F 002 DG9 H12 | Bosch Automotive Service Solutions GmbH 2021-04-08
Maintenance | CS LD 1.0 | 41 | en
30 seconds before shut-down the
display will switch to a countdown
timer with a flashing standby icon. If
the audible alarm is on, it will silence
during this countdown; if the unit
is in Audio OFF mode, the audible
alarm will switch ON and the unit will
beep during the countdown.
Any button press or alarm that oc-
curs will continuously reset the 10
minute internal timer.
7. Maintenance
7.1 Sensor Filter
! To ensure optimum sensor
performance and longevity, the
sensor filter should be replaced
when visibly dirty or when the
message screen in Fig. 12 is dis-
played. The CS LD 1.0 will keep
track of the number of hours of
usage and will advise the user
when it is time to replace the
filter.
Fig. 11: Check sensor filter message
display
ii The warning depicted in Fig. 12
is displayed at power ON when
the CS LD 1.0 internal timer re-
gisters approximately 30 hours
of accumulated use.
7.1.1 Check Sensor Filter
message
When the ‘Check Sensor Filter’
message (Fig. 12) is displayed, the
user is directed to consult this ma-
nual for the following instructions.
It is possible to take one of two
actions at this time:
• Check and replace if necessary,
the filter.
• Postpone filter check until a
subsequent operation.
It is highly recommended to choo-
se the first option.