Region: Here you can set motion detection zone. See Motion detect region setup, page
59
Sensitivity: Set the threshold for motion detection from 1 to 6 (default). The sixth level
has the highest sensitivity.
Period: Click Setup for a new interface screen where you can organize time periods for
detect activation – see Period, page 60.
Alarm out: If an alarm occurred, the system will enable a peripheral alarm device
connected to the selected outputs (default is 1).
Show message: System can pop up a message to alarm you in the local host screen if you
enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm centre)
if you enabled current function.
Send email: an alert email is sent when an alarm is detected.
PTZ activation: Here you can set PTZ movement when an alarm occurs. See PTZ activation,
page 61.
Tour: Here you can enable the tour function when an alarm occurs. The system supports
only one-window tour. See Display, page 63 for how to setup the tour interval.
Snapshot: Select to snapshoot an image from the chosen camera(s) when an alarm
occurs. For snapshot operation, see Encode, page 39.
Sequence Mon. B: Select to activate a tour on monitor B. See Display, page 63 for how
to setup the tour interval.
Buzzer: Select here to activate the buzzer when an alarm occurs.
After completing setup, click <Save> to save your settings and go back to the previous menu.
Note: In the Detect menu, the Copy function is only valid for the same event type, which
means you cannot copy a channel setup in video loss mode to camera masking mode.
58 en | Configuration