Configuration and walk test
Before placing the motion detector body on the base, and before performing a walk test,
configure the features and options located on the motion detector body.
Look-down zone
The motion detector has a manual cam to enable or disable the look-down zone. Enable the
look-down zone when the motion detector must detect motion in the area under the sensor.
To reduce false alarms, disable the look-down lens for locations where small animals are likely
to cross the look-down zone.
The following figure shows how to enable and disable the look-down zone. Turn left to disable
the look-down zone. Turn right to enable the look-down zone.
ON
1 2
Figure 7.1: Setting the optional look-down zone
Walk test LED
The walk test LED indicates the motion detector condition, depending on status.
2 min
During the warm-up period (after providing power to the
device), the LED flashes continuously until the device is
ready for use.
During walk test, the LED indicates simultaneous PIR and
microwave activity (dual alarm).
If the motion detector is in a self test fault condition, the
LED flashes 4 times repeatedly.
If the motion detector is in a low power supply fault
condition, the LED flashes 5 times repeatedly.