Installation and Maintenance Manual
LV MODEL
8733944336 (2016/09)

Table of Contents

Questions and Answers

  • N
    Nathan FrancisAug 25, 2025
    What to do if my Bosch LV015 compressor isn't running and the fan is on, but I suspect low refrigerant?
    • P
      Paul HayesAug 26, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a low-pressure fault caused by low refrigerant. Check the refrigerant pressure with a gauge set.
  • D
    Danielle LeeAug 23, 2025
    How to reduce objectionable noise levels from my Bosch LV015 Heat Pump?
    • R
      Rachel NelsonAug 23, 2025
      If you're experiencing objectionable noise levels from your Bosch Heat Pump, ensure the duct work and grilles are properly sized for unit air flow. If the fan speed setting is too high, consult the blower performance table and reduce fan speed if possible. To address structure borne noise, mount the unit on a vibration pad. Also, install the unit in accordance with the provided instructions and adjust the unit location to prevent it from touching the structure.

Summary

Safety and Symbol Reference

Safety Warnings

Provides critical safety information before installation and servicing.

Installation - Location and Mounting

Unit Mounting Procedures

Details on how to mount vertical and horizontal units, including vibration pads and pitching.

Installation - Duct System and Condensate Drain

Condensate Drain Installation

Procedures for installing the condensate drain line, including slope and trap requirements.

Installation - Piping and Power Supply

Field Power Supply Wiring

Instructions for wiring the high voltage power supply to the unit according to codes.

Installation - Low Voltage and Control Wiring

Installation - Field Control Wiring

Unit Protection Module (UPM) and Safety

Key Safety Features and UPM Functionality

Lists safety features and UPM board functions like anti-short cycle and freeze protection.

Pre-Start-Up System Checks

Pre-Start-Up System Checkout

Checklist of essential system checks before initial unit startup.

Unit Start-Up Procedures

Cooling and Heating Mode Start-Up

Steps for starting the unit in cooling/heating modes and verifying performance.

Water Quality Management

Unit Troubleshooting Guide

Troubleshooting: No Compressor, Fan Runs

Diagnosing and resolving issues when the compressor doesn't run but the fan does.

Troubleshooting: Freeze Faults

Diagnosing freeze faults related to water flow or low refrigerant.

Troubleshooting Common Issues

Troubleshooting: Condensate, Brown Out, and Air Coil Freeze Faults

Diagnosing issues with condensate, low voltage, brown outs, and air coil freeze faults.

Troubleshooting: Thermostat and Reversing Valve Issues

Addressing thermostat connection problems and reversing valve operation.

Troubleshooting Component Failures

Troubleshooting: Compressor and Power Supply Issues

Diagnosing compressor faults, power supply problems, and control transformer issues.

Troubleshooting: PSC Fan Motor Issues

Diagnosing issues with PSC fan motors, including faulty motors or relays.

Troubleshooting Operational Problems

Troubleshooting: ECM Fan Motor and Cooling Shift Issues

Diagnosing ECM motor faults and problems with the unit not shifting into cooling.

Troubleshooting Environmental and Noise Issues

Wiring Diagrams

Maintenance and Environmental Protection

Bosch LV015 Specifications

General IconGeneral
RefrigerantR410A
Cooling Capacity5.0 kW
Sound Level45 dB
Heating Capacity16, 000 BTU/h
Noise Level (Outdoor Unit)45 dB
Weight (Indoor Unit)12 kg
Weight (Outdoor Unit)35 kg
Dimensions (Indoor Unit)700 x 250 x 190 mm
Dimensions (Outdoor Unit)780 x 290 x 540 mm