26 en | Camera MIC IP ultra 7100i │ MIC IP starlight 7100i
2020-11 | 1.4 |
User Manual
Bosch Security Systems
Blue Gain
The blue gain adjustment offsets the factory white point alignment (reducing blue introduces
more yellow). It is only necessary to change the white point offset for special scene
conditions.
Sodium red level
Adjust the level of red for sodium vapor lighting with the slider from 0 to 255.
Sodium blue level
Adjust the level of blue for sodium vapor lighting with the slider from 0 to 255.
Note: The fields Sodium red level and Sodium blue level appear only when the value in the
field White balance is “Sodium lamp auto” or “Sodium lamp.”
Saturation
Select the percentage of light or color in the video image. The range of options is from 60% to
200%; the default is 100%.
Color hue
Select the degree of color in the video image. The range of options is from -14° to 14°; the
default is 0°.
Exposure and gain control
Gain control
Adjusts the automatic gain control (AGC).
– AGC (default): Automatically adjusts the gain to the lowest possible value needed to
maintain a good picture.
– Fixed: no enhancement. This setting disables the Max. Gain Level option.
Fixed gain
Select the desired number for Fixed gain from the drop-down box.
Maximum gain level
Select the appropriate Maximum gain level (for example, Low, Medium or High) with the
slider.
AE-response speed
Select the speed of the response of auto exposure. Options are Super slow, Slow, Medium
(default), Fast.
Shutter Mode
– Fixed: The shutter mode is fixed to a selectable shutter speed.
– Automatic exposure: increases camera sensitivity by increasing the integration time on
the camera. This is accomplished by integrating the signal from a number of consecutive
video frames to reduce signal noise.
If you select this option, the camera disables Shutter automatically.
Shutter
Adjusts the electronic shutter speed (AES). Controls the time period for which light is
gathered by the collecting device. The default setting is 1x (60 Hz: 1/30, 50 Hz: 1/25)
Maximum automatic exposure
Use this field to limit the integration time when Frame Integration is active. The range of
options is from 1/4 to 1/30 (default).
Default shutter limit
The camera tries to hold this shutter value as long as sufficient ambient light is available in the
scene.