MIC IP ultra 7100i │ MIC IP starlight 7100i Alarm | en 53
Bosch Security Systems
User Manual
2020-11 | 1.4 |
– Time range: If you select this option, then two input fields appear to the right. In these
fields, enter the time range for the activation of the alarm in hours and minutes. (The
default values are 00:00 and 00:00.)
Select one of the following output commands for both Output 1 and Output 2 settings:
Note: Not all options are available for all cameras.
– None: no defined command.
– AUX on: defines a standard or custom keyboard ON command.
– AUX off: defines a standard or custom keyboard OFF command.
– Pre-position: defines a pre-position from shot 1-256. (Note: This option is not available
for the input Time range.)
– Alarm output
Note for MIC IP cameras only:
Alarm output is available only when the field Application variant in the
Application variant,
page 19
is set to [camera name] - IO“ (for a camera connected to MIC-ALM-WAS-24)
Click the checkbox Enabled to activate the alarm.
Click Set to save. The camera’s system activates the alarm rules.