10.4 External connections
10.4.1 Rear panel
The rear panel of the remote control kit has the same
connectors and controls as the rear panel of the
LBB1996/00 Voice Alarm Remote Control. See section
9.3 for connection details.
10.4.2 LEDs
To the LEDS/LAMPS connectors on the front panel of
the remote control kit, the LEDs can be connected (see
figure 10.2).
10.4.3 Lamps
To the LEDS/LAMPS connectors on the front panel of
the remote control kit, lamps can be connected (see
figure 10.3).
10.4.4 Relays
To the LEDS/LAMPS connectors on the front panel of
the remote control kit, relays can be connected (see
figure 10.4).
10.5 Technical data
figure 10.2: Connecting LEDs
figure 10.3: Connecting lamps
24 V output
5k
LEDS/LAMPS
connector
GND
max.52V
LEDS/LAMPS
connector
<200mA
figure 10.4: Connecting relays
EMC emission:
According to EN55103-1
EMC immunity:
According to EN55103-2
Current consumption:
150 mA ( idle )
400 mA (indicator test)
Dimensions:
132.5 x 430 x 90 mm
Weight:
2.2 kg