Bosch Security Systems | 2006-06 | 9922 141 10377 en
Plena Voice Alarm System | Installation and User Instructions | Operation en | 86
24 Switch on and off
24.1 Voice alarm controller
24.1.1 Switch on
Put the Power switch on the rear of the voice alarm
controller (see figure 24.1) in the I position.
If mains power or back-up power is available, the power
indicator on the front of the voice alarm controller is lit
(see figure 24.2). If the system contains call stations, the
power indicator of the call stations are also lit (see figure
7.1, no. 1). Furthermore, all connected remote controls
and remote control extensions are switched on by the
voice alarm controller.
24.1.2 Switch off
Put the Power switch of the voice alarm controller (see
figure 24.1) in the O position.
24.2 Voice alarm router
24.2.1 Switch on
Put the Power switch on the rear of the voice alarm
router in the I position.
24.2.2 Switch off
Put the Power switch of the rear of the voice alarm
router in the O position.
24.3 Calibration
Calibration is necessary for a correct loudspeaker line
impedance supervision (see section 18.11). To calibrate
the system, push the calibration switch on the rear of the
voice alarm controller (see figure 5.1, no. 24). The
system must be calibrated:
When the voice alarm controller is switched on for
the first time.
When a voice alarm router is switched on for the
first time.
After the connected loudspeakers are changed.
After loudspeakers have been added.
After the settings of the connected loudspeakers have
been changed.
Note
It is assumed that the APR mode switch (see
section 17.3) is in the OFF position.
figure 24.1: Power switch
figure 24.2: Power indicator
Note
When the system is switched on for the first
time and supervision is enabled, calibrate the
system (see section 24.3).
115V~
230V~
Apparatus delivered
Connected for 230V~
Power
Processor reset
Network
Call/EMG
Music/Spare
Ground short
Input
Mains
Battery
Zone1
Zone2
Zone3
Zone4
Zone5
Zone6
Fault Indicators
A
B
Disabled
Message
EMG mic
RCP
Router
0dB
-6dB
-20dB