38/64 Installation
Bosch Rexroth AG, A4VG Series35, RE92035-01-B/2019-11-25
1
2
2
4
3
Fig. 12: Removing transportprotection
1 Protective covers
2 Protective plugs/threaded plugs
3 Protective covers for sensors and
connectors
4 For version with through drive,
protective cover and mounting bolts
Ports intended for connecting lines come with protective plugs and/or threaded
plugs, which serve as transportprotection. Connect all ports required for
functional operation (see Table 10 "Ports A4VG series35Series35" on
page41). Failure to do so could lead to malfunctions or damage. If a portis not
being used, plug it with a threaded plug since the protective plugs are not
pressure-resistant.
Setting screws are protected against unauthorized adjustment by tamper-proof
caps. Removal of the tamper-proof caps will void the warranty. If you need to
change the settings, please contact your local contact person; you can find their
contact information at
www.boschrexroth.com/addresses
3. For versions with through drive, install the auxiliary pump according to the pump
manufacturer's instructions. The protective cover(4) is not pressure-resistant and
is therefore not permitted during operation.