Installation 41/64
RE92035-01-B/2019-11-25, A4VG Series35, Bosch Rexroth AG
Table 10: Ports A4VG series35
Ports
1)
p
max
[bar]
2)
State
3)
A, B Working port 530 O
S Suction port 5 O
4)
T
1
Drain port 3 O
5)
T
2
Drain port 3 X
5)
R Air bleed port 3 X
X
1
, X
2
Control pressure port 30 X
G Boost pressure portinlet 30 X
M
A
, M
B
Measuring portpressure A, B 530 X
6)
F
a
Boost pressure portinlet 30 X
7)
F
e
Boost pressure portoutlet 30 X
7)
1)
The measuring system and thread sizecan be found in the installation drawing.
2)
Depending on the application, momentary pressure peaks can occur. Keep this in mind when
selecting measuring devices and fittings.
3)
O = Must be connected (comes plugged)
X=Plugged (in normal operation)
4)
Plugged for external boost pressure supply.
5)
Depending on the installation position, T
1
or T
2
must be connected
(seechapter7.3"Installation position" on page 32)
6)
Pressure sensor mounted or M
A
, M
B
plugged.
7)
Must be connected for filtration in the pressure line.
The following tightening torques apply:
Fittings:
Observe the manufacturer's specifications regarding the tightening torques of the
fittings used.
Female threads in the axial piston unit:
The max. permissible tightening torques M
G max
are the maximum values for the
female threads and should not be exceeded. For values, seeTable 11.
Threaded plugs:
For the metallic threaded plugs supplied with the axial piston unit, the required
tightening torques of threaded plugs M
V
apply. For values, seeTable 11.
Mounting bolts:
For mounting bolts with DIN13 metric ISO threads, we recommend checking the
tightening torque individually in accordance with VDI2230.
In addition to the ports specified in Table 10 "Ports A4VG series35Series35"
on page41, axial piston units may have openings that are also closed with
athreaded plug. These plugs must not be opened on the customer side! If you
have opened the threaded plug accidentally, please contact your local contact
person to ensure safe re-closing of the plug. You can find the address at
www.boschrexroth.com/addresses