EasyManua.ls Logo

Bosch Rexroth Indramat ECODRIVE DKC02.1 Series - Page 75

Bosch Rexroth Indramat ECODRIVE DKC02.1 Series
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ECODRIVE DKC02.1 Drive Controller Power connection 11-5
DOK-ECODRV-DKC02.1****-PRJ2-EN-P
AP5110D4.fh5
K1
Limit switch
E-stop
Power off
Power on
Control error
message
Mains contactor
External control +DC 24 V
1)
Integrate Bb contact of additional DKCs and BZM into the series connection
2)
E-Stop for additional DKCs on same mains contactor
3)
Switching capacity DC 24V/1A
4)
Use overvoltage limiter with diode combination
Bb
3)
X4/3
2)
X4/6
1)
K1
4)
E-STOP
DKC ready to operate
0V
Fig. 11-6: Principal control circuit to the DKC
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01