Set the address for each KSM/KMS with the H and L rotary switches. The ro‐
tary switches are hidden under the X103.1 and X103.2 connector hoods.
H Address selector switch (×10)
L Address selector switch (×1)
Fig.5-5: Address Selector Switch
Setting Description
"00"
H = 0
L = 0
"00" is the factory setting of the address selector switches.
This setting is not applied. The individual drive address must be
set in parameter "S‑0‑1040, Drive address of master
communication".
"01" … "99"
H = 0 … 9
L = 0 … 9
Drive address =
H×10 + L
Settings of the address selector switches are applied to
"S‑0‑1040, Drive address of master communication" during the
booting process.
Example for setting drive address "14":
H = 1, L = 4 ⇒ drive address = 1×10 + 4 = 14
See also documentation Parameter Description:
"S‑0‑1040, Drive address of master communication"
"S‑0‑0096, Slave arrangement (SLKN)"
Fig.5-6: Setting the Drive Address at H and L
Order in drive line
The order of the addresses in a line can be selected as desired.