C Protective cap
M12 4-pin socket, D-coded; the pins are internally connected to the con‐
tacts for Multi-Ethernet communication (Tx+, Tx-, Rx+, Rx-); the con‐
nection point can be used for engineering the drive system
Fig.5-10: Terminal Connector RHS0014
Fig.5-11: Internal M12 Socket Wiring
If it is difficult to access the M12 socket in your drive system:
Connect a cable (e.g. RKB0043) to the M12 socket and position
the end of the cable at an easily accessible point.
Bosch Rexroth AG DOK-INDRV*-KSM02*UL***-IN01-EN-P
Rexroth IndraDrive Mi Distributed Servo Drive KSM02
44/81
Instructions for Use