256/263 Bosch Rexroth AG | Tightening Technology 3 608 870 A47
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2017-
601 4 WLAN configuration read error The WLAN configuration cannot be read
by the internal memory.
Reboot nutrunner
Repeat WLAN configuration
Reset the WLAN settings to default in
NEXO-OS
Update firmware
700 1 Open Protocol: Incomplete pro-
gram selection
Incorrect initialization of program selection
bits.
Apply all program selection bits to the Open
Protocol PLC interface or remove them
701 3 Open Protocol: Incorrect configura-
tion
The Open Protocol configuration cannot
be read by the internal memory.
Reboot nutrunner
Repeat Open Protocol configuration in
NEXO-OS
Reset the Open Protocol settings to default
in NEXO-OS
Update firmware
702 0 Open Protocol: Blocking failed
800 1 Job: Initialization error The mode file read by the internal memory
cannot be read.
Create or import the mode again
Use backup
801 3 Job: Job number not available A job selected for execution cannot be
found in the nutrunner memory.
Create the job again or check job selection
802 1 Job: Execution error The job file read by the internal memory
cannot be read.
Create or import the job again
Use backup
Table 11–3: Error description