6.2.2 Output signals
Overview of PLC output signals
Signal Function Description
Ack0-7 Acknowledge 0-7 Acknowledges program selection
ActEnAck Active enable acknowledge Acknowledges enabling of a single tightening process
ActScanAck
1
)
1. Supported as of Nexo firmware version 1100
Active scanner acknowledge Acknowledges enabling of a single scan process
AnglH Angle too high Angle too high
AnglL Angle too low Angle too low
AppOut0-15 Application Out Bit 0-15 Application-specific output signal
BattOk Battery OK Checks the battery pack slide-in module
BattOff Battery OFF The battery pack slide-in module has been removed
CntSelAck0-7 Counter Select acknowledge Bit 0-7 Acknowledge counter set selection
CcwAck Counter clock wise acknowledge Acknowledges a loosening operation
CntCanceled Counter canceled Counter set canceled
CcwLockAck Counter clock wise lock acknowl-
edge:
Acknowledges that loosening is disabled
CCwSel Counterclockwise Select Loosening program selected at nutrunner
CwAck Clock wise acknowledge Acknowledges a start
CwLockAck Clock wise lock acknowledge Acknowledges that start is disabled
CntNOK Counter NOK NOK counter has reached default value
CntOK Counter OK OK counter has reached default value
CyCmp Cycle Complete Process end
CheckTool Check the tool Nutrunner test interval reached
EnAck Enable acknowledge Acknowledges enabling
EnScanAck
1)
Enable scanner acknowledge Acknowledges that the scanner is enabled
FtpF Ftp Fault Results transfer error
InCy In Cycle Tightening program active
InCyCcw In Cycle Counterclockwise Loosening is active
JobAck0-7
1)
Job acknowledge 0-7 Acknowledges the selected job
JobCyCmp
1)
Job Cycle Complete The job is finished
JobIncy
1)
Job In Cycle The job is active
JobNOK
1)
Job Not OK The job result is not okay
JobOK
1)
Job OK The job result is okay
JobRdy
1)
Job ready The job is ready
ManOpAck
2
)
2. Supported as of Nexo firmware version 1300
Manual Operating Mode acknowl-
edge
Manual mode acknowledgment
NF No Fault Nutrunner without system errors
NOK Not OK Result not OK
OK OK Results OK
RC0-4
1)
Rework Code Bit 0-4 Rework code Bit 0-4
Rdy Ready Nutrunner ready for operation
ScanRdy
1)
Scanner ready Scanner ready
ScanRxID
1)
Scanner read ID Barcode read
StartBn Start button State of the start switch
TimeH Time too high Time too high
TorqH Torque too high Torque too high
TorqL Torque too low Torque too low

Table of Contents