9.5.2 Mode steps
A mode always begins with the start step and ends with the end step; the two steps are preset.
9.5.3 Change mode
You can change the mode.
Accept values
Click OK to apply the edited values to the mode. Click Cancel to discard your changes.
The dialog window will be closed in either case.
Click Save to apply the mode.
9.5.3.1 Operating mode step
As of Nexo firmware version 1300, the operating mode (manual mode or automatic mode) can be select-
ed for the Nexo cordless Wi-Fi nutrunner.
Settings
9.5.3.2 Start step
Every operating mode has exactly one start step. The properties of the start step apply to the relevant
operating mode.
In this step, define the settings for the operating modes and for the identification code which identifies a
result data record of the Nexo cordless Wi-Fi nutrunner.
Table 9–10: Available mode steps
Element Designation Explanation See page
Operating mode step As of Nexo firmware version 1300.
Determination which operating mode will be ac-
tive after restart or mode storage
(page 185)
Start step Start of the mode (page 185)
ID input Adds an ID input step. A maximum of two ID input
steps can be added.
(page 186)
End step End of the mode (page 188)
Double clicking the operating mode step or the respective icon will open a dialog where
the associated parameters can be entered.
Table 9–11: Operating mode step dialog
Element Description
Active column selection Determination which operating mode will be active after restart or mode stor-
age.
Double clicking the start step or the respective icon will open a dialog where the associ-
ated parameters can be entered.