22/44 Bosch Rexroth AG SYHNC100-SEK...3X | RE 30162-B/04.11
Assembly
Assembly6
NOTE
Risk of short circuit!
Water may condense within the housing!
Let the SYHNC100-SEK...3X acclimate itself for several hours, as otherwise
f
water may condense in the housing.
The housing of the SYHNC100-SEK...3X is perforated. According to the existing
protection class, dirt and fluids may easily enter and cause failures and a short
circuit! Safe functioning of the SYHNC100-SEK...3X is thus no longer ensured.
When working on the SYHNC100-SEK...3X you must make sure that
f
everything is clean and that no fluids will enter the housing.
Major potential differences!
Danger of destroying the SYHNC100-SEK...3X by connecting or disconnecting
plug-in connectors under voltage.
Switch off power supply to the relevant system component before assembling
f
the unit or when connecting and disconnecting plug-in connectors.
Installation conditions6.1
For installing the product always observe the environmental conditions f
specified in the data sheet RE 30162.
NOTE: The environment must be free from electrically conductive contamination
(acids, bases, corrosive agents, salts, metal vapors, etc.) and the device must not
be exposed to these substances. Rule out any deposits according to protection
class IP 20.
The SYHNC100-SEK...3X is intended for top hat rail assembly in the control
cabinet. The dimensions of each version are listed in the data sheet RE 30162.
Before commissioning, make sure that all the seals and plugs of the plug-in
f
connections are installed correctly and undamaged to ensure that fluids and
contamination parts are prevented from penetrating the product.