36/44 Bosch Rexroth AG SYHNC100-SEK...3X | RE 30162-B/04.11
Commissioning
Commissioning7
First commissioning7.1
NOTE
Uncontrolled connection or disconnection of plug-in connectors!
The device might be destroyed.
Before installation works, and before connecting or disconnecting plug-in
f
connectors to or from the device, the device must be disconnected from the
voltage supply or reliably de-energized.
Devices damaged due to incorrect installation are not covered by the
warranty.
Observe protection class, voltage supply and environmental conditions
f
according to data sheet RE 30139.
There are the following prerequisites for the functioning of the SYHNC100-SEK...3X:
The WINPED® 6.6 operating software has to be used.
There must be an application project on the SYHNC100-SEK...3X. If no
application project is available, please contact
support.ncsystems@boschrexroth.de.
The application project must also be available on the PC so that the
SYHNC100-SEK...3X can be initialised and/or the parameterization and
diagnosis can be completed.
Further information on operation, project planning, programming and diagnosis
of the control system with WIN-PED® 6.6 is available in the help menus of the
program.
Commissioning software WIN-PED7.2 ® 6.6
For commissioning and for later operation, the user can apply the PC program
WIN-PED®. It can be used for the programming, setting and diagnosis of the
SYHNC100-SEK...3X. Functionality, menus and program windows are adjusted to
the variants of the SYHNC100-SEK...3X.
WIN-PED® offers the following functions:
Convenient dialog functions for the online or offline settings of the machine data
Dialog window for the online setting of the parameter values
Various options for the display of the process parameters, the digital inputs,
outputs
Recording and graphic illustrations of up to 16 process parameters with a great
choice of trigger options
The PC program WIN-PED® 6.6 is not included in the scope of delivery of the
VT-HNC100...3X. Download on the Internet:
www.boschrexroth.com/hnc100