12/60 General notes on damage to material and the product
Bosch Rexroth AG, VT-VPCD, RE 30028-B/09.13
3 General notes on damage to material and
the product
The warranty is valid exclusively for the configuration delivered.
t Warranty claims will be rejected in the case of improper installation,
commissioning and operation as well as in the case of use not in accordance with
the intended purpose and/or improper handling.
NOTICE
High voltage!
Possible damage to the control electronics.
▶ Wire the control electronics only when it is disconnected from the power supply.
Overheating!
Possible damage to the control electronics.
▶ Adhere to the ambient conditions according to the data sheet.
▶ Do not use free-wheeling diodes in the solenoid cables.
▶ Ensure sufficient ventilation of air.
Overloading!
Risk of overloading and damage to supply cables in the case of insufficient
dimensioning and/or operation with several electrical devices.
▶ Provide current limitation by overload protection.
▶ Select an appropriate rating of power supply unit and cables.
Short-circuit!
Risk of overloading of and damage to the supply cable in the case of a defect of
electrical equipment.
▶ Provide current limitation by means of overload protection.
Electrostatic discharge!
Risk of damage to components of the control electronics.
▶ Provide equipotential bonding to discharge static voltage from your body.
▶ Work in a safe environment.
▶ Do not use devices that generate or have static discharge in the working
environment.
▶ Do not carry out any work on the control electronics in environments that could
generate static charges.
▶ Handle the control electronics with care. Do not touch exposed connection pins
and sensitive components of the electronics.
▶ Transport and store the control electronics carefully in the original packaging
provided for this purpose.
Wrong cables! Voltage loss, scorching of cable!
Risk of damage to the product.
▶ For solenoid cables up to 50 m long, use cable type LiYCY 1.5mm², for position
transducer cables, cable type LiYCY 0.5 mm² shielded. For greater lengths,
please consult us.