EasyManua.ls Logo

Bosch Solution 64 - Page 52

Bosch Solution 64
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solution 64
|
Installer Guide
|
Input Programming
7-12
Bosch Security Systems | 11/05 | BLCC110I
Open and close the zone that needs to be tested. When the test
has been completed the keypad will display:
Zn001 Zone 1 Name
Test Successful
Press OK or MENU
Press [OK] or [MENU] to exit.
Inputs > Input Testing >
Sensor Watch Time
MENU 3-9-2
0 3 0
(*** System Wide Parameter ***)
DAYS
This menu programs the Sensor Watch Time interval. Zones
programmed for Sensor Watch are required to seal and unseal
at least once within the Sensor Watch Time period or a trouble
message will be displayed on the keypad and a Zone Trouble
report sent.
Valid entries are 1 -255 Days and 0 = Sensor Watch Disabled
Press [MENU] + [3] + [9] + [2]. The keypad will display the
current sensor watch time (Default = 30 days).
SensorWatch Time
030 Days
Press 0-9 OK or MENU
Using the numeric keys, enter the new Sensor Watch time in
days then press [OK] to save and exit or press [MENU] to exit
without saving.
i
Note
Sensor Watch monitoring is only active when the area is in the
disarmed state. 24 hour zone types cannot be monitored using
the Sensor Watch feature.
» »
E N D O F S E C T I O N
« «