Bosch Security Systems | 11/05 | BLCC110I
2-1
S e c t i o n 2
Installing the Hardware
Mounting the Enclosure
The enclosure should be mounted via 4 (screws/bolts) through
the 4 mounting holes in the base. Ensure that the enclosure
is mounted on a solid, at, vertical surface such that the base
will not ex when tightened. Enclosure dimensions are shown
below.
375
257
90
Figure 1 : Enclosure Dimensions
Module Spaces
Each enclosure has 4 identical module spaces and 1 large
module space that is allocated for non Bosch PCB boards (eg. a
securitel STU).
Each space includes 4 x 10mm stand-os that the optional
expander PCB boards will mount using screws (screws will
be supplied with each board). The expander board will be
earthed via the screws that mount the PCB to the metal box.
All Bosch modules will mount on these module spaces.
A list of the PCB boards is detailed below
Module Space Occupied
Solution Control Panel 2 Adjacent Module Spaces
CM100 Voice Command Module 1 Module Space
CM110 Output Expander 1 Module Space
CM120 LAN Power Supply 1 Module Space
CM130 RS232 Port Expander 1 Module Space
CM140 GSM Modem Interface 1 Module Space
CM150 TCP/IP Interface 1 Module Space
Using the above table, the installer can determine how
many modules can be mounted in a single enclosure. On
some export models, module 3 will not be available as the
transformer mounts in this location.
Figure 2: Metal Box – Module Space Allocations
Panel LED Indicators
The Solution 64 PCB has two LED indicators (Dialler and Status
LED’s) which display the following information.
Red Dialler LED
Condition
Meaning
O Oine
On On Line (Dialling/Answered)
Flashing Incoming Call
Table 1: Dialler LED Meanings
Green Status LED
Condition
Meaning
O Error
On Error
Flash Once Every 2 Seconds OK
Slow Flash Waiting for Direct Connect
Flash Fast AC or Battery Trouble
Table 2: Status LED Meanings
i
Note
During factory defaulting the Status and Dialler LED indicators
will be on steady for approximately 15 seconds.