Solution 64
|
Installer Guide
|
Area Programming
6-6
Bosch Security Systems | 11/05 | BLCC110I
Using the numeric keys, enter the new account number. Use
the up and down arrows to select special characters BCDEF.
Account Dest 2 A001
1604000000
Press 0-9 OK to SAVE
Press [OK] to save and exit or press [MENU] to exit without
saving.
Areas > Reporting >
Open / Close Route
MENU 2-2-2
0 = Report Events To Log Only 1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
This menu programs the destination for open and close
reports. Only one option can be programmed in this menu.
Enter [MENU] + [2] + [2] + [2] and select the area from the list
then press [OK].
Use the numeric keys 0-9 or the up and down arrow keys to
sellect the desired option.
Open/Close Route A001
01-Dest 1 + Log
Press 0-9 OK to SAVE
Press [OK] to save and exit or press [MENU] to exit without
saving.
Area Te s t i n g
Areas > Area Testing >
Area Watch
MENU 2-9-0
0 1 2
(*** System Wide Parameter ***)
WEEKS
This menu programs the number of weeks (001 – 255 weeks /
000 = disabled) an area can remain disarmed before registering
an ‘Inactivity Interval’ report. A restore signal will be sent when
the area is next armed and the exit time expires.
Enter [MENU] + [2] + [9] + [0] . The keypad will display the
current number of weeks programmed for area watch.
Area Watch
012 Weeks
Press 0-9 OK to SAVE
Using the numeric keys, enter the number of weeks that an
area can remain turned o betore a trouble condition will
occur. Valid entries are 1 – 255 Weeks or 000 to disable.
Press [OK] to save and exit or press [MENU] to exit without
saving.
2)
3)
1)
2)
3)
1)
2)
3)
Areas > Area Testing >
User Test Interval
MENU 2-9-1
0 0 0
(*** System Wide Parameter ***)
DAYS
This menu sets the number of days before it will prompt the
user to walk test the system. To clear the trouble condition, you
will need to perform the ‘Walk Test’ function.
Enter [MENU] + [2] + [9] + [1]. The keypad will display the
current number of weeks between User Test intervals.
User Test Interval
000 Days
Press 0-9 OK to SAVE
Using the numeric keys, enter the number of days between
each user test interval. Valid entries are 1 – 255 Days or 000 to
disable.
Press [OK] to save and exit or press [MENU] to exit without
saving.
Areas > Area Testing >
Service Interval
MENU 2-9-2
0 5 2
(*** System Wide Parameter ***)
WEEKS
This menu sets the number of weeks between service intervals.
When a service interval is due, a trouble condition will display
on the keypad to remind the customer that a system check is
required by the security company. When viewing the trouble
condition, the keypad will display ‘Call For Service’. To clear the
trouble condition, the installer must enter and exit installer’s
programming mode.
Enter [MENU] + [2] + [9] + [2]. The keypad will display the
current number of weeks between user test intervals.
Service Interval
052 Weeks
Press 0-9 OK to SAVE
Using the numeric keys, enter the number of weeks between
each user Service Interval. Valid entries are 1 – 255 Weeks or
000 to disable.
Press [OK] to save and exit or press [MENU] to exit without
saving.
1)
2)
3)
1)
2)
3)