Solution 64
|
Installer Guide
|
Output Programming
Bosch Security Systems | 11/05 | BLCC110I
8-9
Output Event Ty p e Ta b l e
0 = Disabled
1 = Battery Trouble P 26 = Entry Time A 51 = Senior Watch A
2 = AC Trouble P 27 = Exit Time A 52 = Exit Error A
3 = Telephone Line Trouble P 28 = End Of Exit Time A 53 = RF Key Fob Function 1 A
4 = Comm Fail – Destination 1 / 2 P 29 = Chime On A 54 = RF Key Fob Function 2 A
5 = Third Dialler Attempt P 30 = Chime Zone Triggered A 55 = Output Pre- Alert A
6 = Destination 1 Reporting P 31 = Auto Arm Pre-Alert A 56 = Follow PIN Code U
7 = Destination 2 Reporting P 32 = Ready To Arm All On A 57 = Part Entry Time A
8 = Destination 1 or 2 Kiss O P 33 = Ready To Arm Part On A 58 = Time Schedule S
9 = Destination 1 Kiss O P 34 = Ready To Arm Part 2 On A 59 = Temperature Alarm K
10 = Destination 2 Kiss O P 35 = Closing Report Sent OK A 60 = Access Group G
11 = Dialler Disabled P 36 = External Siren (Spk Beeps) A
12 = Output Device Missing P 37 = Internal Siren (Spk Beeps) A
13 = Output Trouble O 38 = Alarm Any (silent or Audible ) A
14 = Panel On Line P 39 = Fire Alarm A
15 = Incoming Call P 40 = Burglary Alarm A
16 = System Trouble P 41 = Silent Alarm A (A) = Area Event Assignment
17 = Box Tamper P 42 = Duress Alarm A (P) = Panel Event Assignment
18 = Zone Trouble Z 43 = Keypad Medical A (O) = Output Event Assignment
19 = Zone Mirror Z 44 = Keypad Fire A (Z) = Zone Event Assignment
20 = Zone Alarm Z 45 = Keypad Panic A (U) = User Event Assignment
21 = Area Disarmed A 46 = Device Tamper A (S) = Schedule Event Assignment
22 = Area Armed (Any) A 47 = Access Denied A (G) = Access Group Event Assignment
23 = Area All On A 48 = Strobe A (K) = Keypad
24 = Area Part On A 49 = Smoke Sensor GND A
25 = Area Part 2 On A 50 = Sensor Watch A
Table19: Output Event Types
Output Default Ta b l e
The table below lists the default values for all Output parameters in the Solution 64. Outputs 1 to 3 are High current digital
outputs and Output 4 is the onboard relay output. Outputs 5 to 8 are available when the optional Output Relay Expander Board
(CM110) is tted. Options marked N/A = Not Applicable.
Programming Option Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8
Output Name
External
Siren
Strobe
Light
Smoke
Sensor PWR
Internal
Siren
Output 5
Name
Output 6
Name
Output 7
Name
Output 8
Name
Event Type
36
(External
Siren)
48
(Strobe)
49
(Smoke
Sensor GND)
37
(Internal
Siren)
0 0 0 0
Event Assignment 1 1 1 1 1 1 1 1
Output Polarity 14 6 11 6 0 0 0 0
Time Parameter
N° Of Hours 000 008 000 000 000 000 000 000
N° Of Minutes 005 000 000 005 000 000 000 000
N° Of Seconds 000 000 010 000 000 000 000 000
N° Of 1/10 Seconds 000 000 000 000 000 000 000 000
Output Options
Do not Operate If Low Battery Y Y Y Y N N N N
Display Output Overload Y Y Y N/A N/A N/A N/A N/A
Report Output Overload Y Y Y N/A N/A N/A N/A N/A
Display Missing Output Device Y N N N/A N/A N/A N/A N/A
Report Missing Output Device Y N N N/A N/A N/A N/A N/A
Reserved N N N N N/A N/A N/A N/A
Reserved N N N N N/A N/A N/A N/A
Reserved N N N N N/A N/A N/A N/A
Table 20: Output Default Table