11-6
Bosch Security Systems | 11/05 | BLCC110I
System > Timers >
Part Entry Time
MENU 7-2-3
0 6 0
(*** System Wide Parameter ***)
SECONDS
This menu allows you to program the Part Mode Entry Delay
time also know as entry guard. When armed in Part Mode, all
active zones retain their normal functionality. ie. instant zones
will trigger instantly etc. The part entry timer allows all active
zones to have an entry delay when the the area is armed in
part mode regardless of their normal functionality.This can
help to prevent false alarms when people on site inadvertantly
unseal an active zone.
If a valid PIN code is not entered before the timer expires then
the alarm will trigger. Programming the entry guard time as
zero will disable this feature.
Press [MENU] + [7] + [2] + [3]. The keypad will display the
current Part Entry time.
Part Entry Time
060 Seconds
Press 0-9 OK to SAVE
Using the numeric keys, enter the required delay for the Part
Entry Time in seconds. Valid times are 0 - 255 seconds, 0 = No
Part Entry Time.
Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Timers >
Auto Arm Pre-Alert
MENU 7-2-4
0 1 0
(*** System Wide Parameter ***)
Minutes
This menu allows you to program the Auto Arm Pre Alert count
down timer. The timer is used to warn sta or users that the
system is about to auto arm by sounding a tone on the keypad.
To set up auto arming see MENU 7-5-0 — System Schedules.
If a valid PIN is entered during the pre alert time, the system
will delay the auto arm instruction for 1 hour. This sequence
will repeat on the hour untill the system is armed manually or
automatically.
For example if the system is programmed to auto arm at
8.00pm and the Pre Alert time is set to 10 minutes then at
7.50pm the system will begin sounding the Pre Alert tone on
the keypad. If a valid code is entered the tone will stop and the
system will remain disarmed. At 8.50pm the pre alert tone will
start again. If no code is entered the system will auto arm at
9.00pm.
Press [MENU] + [7] + [2] + [4]. The keypad will display the
current Pre-Alert Time.
Auto Arm Pre Alert
010 Minutes
Press 0-9 OK to SAVE
1)
2)
3)
1)
Using the numeric keys, enter the pre-alert time . Valid times
are 0 to 255 minutes. 0 = No Auto Arm Pre Alert.
Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Timers >
Output Pre-Alert
MENU 7-2-5
0 0 0
(*** System Wide Parameter ***)
Minutes
The panel can be programmed to automatically operate an
output via a schedule, see MENU 7-5-0 — System Schedules.
This menu allows you to program the Output Pre Alert count
down timer. The timer is used to warn sta or users that an
output is about to operate by sounding a tone on the keypad.
Press [MENU] + [7] + [2] + [5]. The keypad will display the
current Output Pre Alert Time.
Output Pre Alert
000 Minutes
Press 0-9 OK to SAVE
Using the numeric keys, enter the pre-alert time. Valid times
are 0 to 255 minutes. 0 = No Output Pre Alert
Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Timers >
Senior Watch Time
MENU 7-2-6
0 0 0
(*** System Wide Parameter ***)
Hours
This feature can be used to verify that an elderly person is OK
or as a dead man timer for an onsite patrolman or security
ocer.
This menu allows you to program the Senior Watch Time
period. The panel must register at least one burglary zone in
the programmed area op unseal and reseal during this time
period or the panel will report a Senior Watch alarm to the
base station.
A Senior Watch Restore will be sent when at least one zone is
usealled and resealled. Senior Watch monitoring is only active
when the corresponding area is in the disarmed state.
Press [MENU] + [7] + [2] + [6]. The keypad will display the
current senior watch time. (default = 0 hours).
Senior Watch Time
000 Hours
Press 0-9 OK to SAVE
Using the numeric keys, enter the new senior watch time. Valid
times are 0 to 255 hours. 0 = No Senior Watch Time.
Press [OK] to save and exit or press [MENU] to exit without
saving.