16 Tjekliste for sikkerhedstjek USA.fm • Page 41Bale press X-series
Check the door switch (M) (all models)
Open door (F) and press the green start button (B).
(On AD models door (G) must be closed).
The baler must not be able to start.
Close door (F) and press the green start button (B).
Open door (F) after about 10 seconds.
The baler must stop immediately.
It must not be possible to start the baler until door (F) has
been closed again.
Check that the two parts of the door switch (M) are complete
and not defective. (One of the parts of the door switch is on
the door (F), and the other is on the chamber of the baler).
Check the top switch (K) (all models)
Close door (F) and (G) and press the green start button (B).
(On AD models only door (G) must be closed. Press the
green start button (B) twice).
The pump station must stop when the platen (H) reaches the
top position.
You are advised to activate the emergency stop (A) before
visually checking the top switch:
Check that the top switch (K) is intact and free from defects. It
must be possible to move the arm freely.
Deactivate the emergency stop button (A).
Reset the baler with a single push of the green start button
(B).
Check the door switch (L) (only on model X10)
Run the platen down to the lowest position by pressing the
orange finish indicator button (C).
Open door (F) and activate two-hand operation (C) and (D).
The baler must not eject the bale.
Open door (G) and check that the door switch (L) is complete
and not defective. It should be possible to press the roll in and
out.
Check switch (P) (only AD models)
Close door (G) and press the green start button (B).
The AD door (R) will begin to close.
Place an object on the top of the AD door (R), which should
then stop immediately and open again. The pressure exerted
by the object should not exceed a maximum pressure of 3
kilo.
Remove the object and press the green start button (B).