ELECTRIC SYSTEM
KUKJE MACHINERY CO., LTD.
165
7. TROUBLE SHOOTING
CHARGING SYSTEM
Symptom Probable Cause Solution Reference
Fuse blown(10A) Replace
Wiring harness disconnected or improperly
connected (between main switch AC terminal and
panel board, between panel board and dynamo)
Repair or Replace
Dynamo defective Repair or Replace
Charging Lamp
Does Not Light
When Main
Switch Is Turned
ON
Regulator defective Replace
Wiring harness disconnected or improperly
connected (between main switch 30 terminal and
alternator, between panel board and dynamo)
Repair or Replace
Dynamo defective Repair or Replace
Charging Lamp
Does Not Go Off
When Engine Is
Running
Regulator defective Replace
LIGHTING SYSTEM
Symptom Probable Cause Solution Reference
Fuse blown(20A) Replace
Bulb Blown Replace
Head light Does
Not Light
Wiring harness disconnected or improperly
connected (between main switch AC terminal and
combination switch B1 terminal, between
combination switch 1 terminal and headlight
Repair or Replace
Fuse blown(20A) Replace
Bulb blown Replace
Tail Light Does
Not light
Wiring harness disconnected or improperly
connected (between main switch AC terminal and
combination switch B1 terminal, between
combination switch T terminal and tail light)
Repair or Replace
Fuse blown(10A) Replace
Bulb blown Replace
Illumination
Light Does Not
Light
Wiring harness disconnected or improperly
connected (between main switch AC terminal and
combination switch B1 terminal, between
combination switch T terminal and panel board)
Repair or Replace