ELECTRIC SYSTEM
KUKJE MACHINERY CO., LTD.
168
『CAUTION』
9 To avoid accidental short circuit, be sure to attach the positive cable to the positive terminal
before the negative cable is attached to the negative terminal.
9 Never remove the battery cap while the engine is running.
9 Keep electrolyte away from eyes, hands and clothes. If you are spattered with it, wash it away
completely with water immediately.
9 Keep open sparks and flames away from the battery at all times. Hydrogen gas mixed with
oxygen becomes very explosive.
◆ IMPORTANT
9 If the machine is to be operated for a short time without battery (using a slave battery for
starting), use additional current (lights) while engine is running and insulate terminal of battery.
If this advice is disregarded, damage to alternator and regulator may result.
[1] CHECKING AND ADJUSTING
(1) Battery
Battery Voltage
1. Stop the engine and turn the main switch off.
2. Connect the COM (-) lead of the voltmeter to
the battery’s negative terminal post and the (+)
lead to the positive terminal post, and measure
the battery voltage.
3. If the battery voltage is less than the factory
specification, check the battery specific gravity
and recharge the battery.
Battery voltage Factory spec. More than 12V
8. CHECKING DISASSEMBLING AND SERVICING