EasyManua.ls Logo

Branson 900IW+ Series - Page 77

Branson 900IW+ Series
108 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error
Code
Description
Error 26
PALM BUTTON 2 Lost
Non-Latching —
PALM BUTTON 2 was
lost before the trigger became active
Error 27
Error 28
Error 29
Error 30
Error 31
Error 32
Error 33
Error 34
SV Safety Error
Non-Resettable
SV drive safety circuit is not
working. This error cannot be cleared by RESET, or by the
external RESET input.
PALM BUTTON 2 Stagger Error
Non-Latching —
PALM
BUTTON 2 was not pressed within 100 ms after PALM
BUTTON 1 was pressed.
PALM BUTTON 1 Stagger Error
Non-Latching —
PALM
BUTTON 1 was not pressed within 100 ms after PALM
BUTTON 2 was pressed.
Time Limit Error
Latchable —
Minus time limit not reached.
Collapse Limit Error
Latchable —
Plus collapse limit exceeded
or minus collapse limit not reached.
Absolute Limit Error
Latchable —
Plus absolute limit
exceeded or minus absolute limit not reached, or weld
aborted because of overload.
Time Limit Setup Error
Latchable —
Value for minus limit
greater than value for plus limit, or minus limit greater than
nominal value, or plus limit less than nominal value
Collapse Limit Setup Error
Latchable —
Value for minus limit
greater than value for plus limit, or plus limit less than
nominal value.