Error
Code
Description
Error 26
PALM BUTTON 2 Lost
Non-Latching —
PALM BUTTON 2 was
lost before the trigger became active
Error 27
Error 28
Error 29
Error 30
Error 31
Error 32
Error 33
Error 34
SV Safety Error
Non-Resettable
SV drive safety circuit is not
working. This error cannot be cleared by RESET, or by the
external RESET input.
PALM BUTTON 2 Stagger Error
Non-Latching —
PALM
BUTTON 2 was not pressed within 100 ms after PALM
BUTTON 1 was pressed.
PALM BUTTON 1 Stagger Error
Non-Latching —
PALM
BUTTON 1 was not pressed within 100 ms after PALM
BUTTON 2 was pressed.
Time Limit Error
Latchable —
Minus time limit not reached.
Collapse Limit Error
Latchable —
Plus collapse limit exceeded
or minus collapse limit not reached.
Absolute Limit Error
Latchable —
Plus absolute limit
exceeded or minus absolute limit not reached, or weld
aborted because of overload.
Time Limit Setup Error
Latchable —
Value for minus limit
greater than value for plus limit, or minus limit greater than
nominal value, or plus limit less than nominal value
Collapse Limit Setup Error
Latchable —
Value for minus limit
greater than value for plus limit, or plus limit less than
nominal value.
900IW+
4-27
Operation