Error
Code
Description
Error 11
ULS Exit Error
Non-Latching —
The ULS input did not become
active within 4 seconds of SV drive deactivation (time after
IRS has become inactive).
Error 12
PTS Exit Error
Latchable —
The ULS did not become inactive
within allowed time in pretrigger mode.
Error 13
TRS Exit Error
Non-Latching —
The IRS input did not become
inactive within 4 seconds of SV drive deactivation (allowed
time).
Error 14
PBS Exit Error
Non-Latching —
The PB inputs did not become
inactive within 4 seconds of SV drive deactivation, or were still
active after power-up or after E-STOP inputs have been
deactivated (within 4 seconds of the ULS becoming inactive).
Error 15
TRS Weld Error
Latchable —
The TRS input became inactive
during weld or hold timing (before the ULS became inactive).
Error 19
Error 21
Error 25
Power Supply Overload Error
Latchable —
The SPM/AT
indicated a power supply overload after the first 60 ms of
operation.
SV Active Error
Non-Resettable —
The SV drive output did not
meet the requirements for activating the SV. This error cannot
be cleared by RESET, or by the external RESET input.
SV Deactive Error
Non-Resettable —
The SV drive output did
not meet the requirements for deactivating the solenoid valve.
This error cannot be cleared by RESET, or by the external
RESET input.