Description of the Unit
4-13
Digital Compact
2002 BRANSON Ultrasonics Digital Compact Version 22.08.2002
To setting a mode, press the Reset button. After approx. 3 seconds, the
power bar LED will display the value adjusted. You can change this
value using the potentiometer. On the power bar LED
1 red bar corresponds to 50ms (in case of time control)
1 red bar corresponds to 50 Joule (in case of energy control).
In order to enable precise adjustment, each red bar is divided into 20
green or orange bars, a green/orange bar corresponding to 2.5 ms/2.5
Joules.
4.7.1 Basic Mode
After releasing an external start signal, ultrasonics will be output for as
long as the external start signal is present.
4.7.2 Time Mode
By releasing an external start signal (impulse start), you start the weld
time adjusted in the power supply.
After the internal time has elapsed, the weld cycle is terminated. The
external start signal length must be at least 20 ms.
4.7.3 Energy Mode
By releasing an external start signal, the energy weld adjusted in the
power supply is started. The start signal must be present over the
entire length of the weld cycle. If the start signal is lost before the weld
cycle is completed, the weld is terminated immediately, and a Window
low error is output.