Troubleshooting
7-2
Digital Compact
7.2 Error Elimination Tables
7.2.1 Fuses/Circuit Breaker
NOTE!
If a fuse or circuit breaker responds more than once in a row, this
usually indicates that a different component is defective.
Continue troubleshooting on other components.
Tab. 7-1 Troubleshooting: Fuses and circuit breaker
Fault Cause and Remedy
The main fuse or the
circuit breaker
responds when the
module is connected
to the mains supply.
Inspect the power supply cable and
replace if necessary.
Check fuse of the line filter module
and replace if necessary.
Main fuse or circuit
breaker responds
during weld cycle.
Check current rating of the plant fuse.
Replace if necessary.
Check the fuse rating. Replace if not
appropriate.
Replace the power supply module. If
this solves the problem, install another
module and send the defective one to
BRANSON Ultrasonics.
Line fuse responds.
Replace the fuse (please refer to Fig.
7-1).