Electrical Connections
6-9
Digital Compact
2002 BRANSON Ultrasonics Digital Compact Version 22.08.2002
Tab. 6-4 DIP switch settings for additional functions
(default settings are bold.)
Function Options Switch Position
Autotune
Seek on power up:
Checks the horn frequency
upon power-up and stores it
in memory
1 - ON
1 - OFF
Autoseek:
Checks the horn frequency
once per minute, timed from
the last activation of ultraso-
nics.
2 - ON
2 - OFF
Auto seek duration
Selects 500 ms (standard)
or 100 ms (short) seek.
3 - ON = standard
3 - OFF = short
Autotune/Memory:
Updates horn frequency
memory at the end of each
welding process.
4 - ON
4 - OFF