Chapter1Installation
Page1
INSTALLATION
SPECIFICATIONS
Width:27¼”
Height:35½”
Depth:28⅝
Weight:225Pounds
FlueSize:3”or4
HopperCapacity:90Pounds(Corn)
(Thiswillvarydependingonfuel)
EPAStatus:Exempt
MaximumBTUInput:50,000BTUwithwholecorn
APPROVED INSTALLATIONS
Alcove,Conventional,MobileHome
PREPARATION
Factorypackagingmustberemoved,andsome
minorassemblyworkisrequiredpriorto
installationanduse.Accesstotherearandsidesof
thestovewillbenecessaryatsomepointintimeso
besuretoleaveampleroomforaccess,otherwise,
bepreparedtomovethestovewhen
necessary.
InstalltheceramicBrickPanelontotherear
combustionwall.T
HISISAREQUIREDCOMPONENT.The
BrickPanelisfragile,sohandlewithcareatall
times.Yourstovewarrantyonlycoversthisitem
fromthermalbreakage.Impactdamageresultingfromdroppingoraccidentalabuseisnotcovered.
AUGERINSTALLATION:InstalltheaugerintotheaugertubeasshowninFigure2.
Theflat
faceoftheaugeristowardthefrontofthestove,andthebevelededgewill
gointotheaugertube.Makesuretheaugerisallthewaytotherearandis
engagedorseatedproperly.
STIR
ROD&BURNPOTINSTALLATION:TheBurnPotmustbesetinto
theBurnPotHolderwiththefuelspreadertowardstherearofthe
stove,asshown.
Insertthestirrodintotheburnpotwiththebeveledconnector
towardtheleft.Alignthebeveledsegmentssothattheholesoneach
piece
align,andinsertthecotterpin.