Chapter๎˜ƒ2๎˜ƒโ€“๎˜ƒOperation๎˜ƒ
Page๎˜ƒ10๎˜ƒ
GENERAL OPERATION
The๎˜ƒfollowing๎˜ƒinformation๎˜ƒshould๎˜ƒhelp๎˜ƒyou๎˜ƒunderstand๎˜ƒhow๎˜ƒyour๎˜ƒSP6000๎˜ƒMultiโ€Fuel๎˜ƒstove๎˜ƒfunctions.๎˜ƒ๎˜ƒBe๎˜ƒsure๎˜ƒto๎˜ƒread๎˜ƒthese๎˜ƒ
instructions๎˜ƒcarefully๎˜ƒso๎˜ƒthat๎˜ƒyou๎˜ƒunderstand๎˜ƒthe๎˜ƒproper๎˜ƒoperation๎˜ƒof๎˜ƒyour๎˜ƒstove.๎˜ƒ๎˜ƒIf๎˜ƒyou๎˜ƒneed๎˜ƒassistance๎˜ƒor๎˜ƒdo๎˜ƒnot๎˜ƒunderstand๎˜ƒthese๎˜ƒ
directions๎˜ƒyour๎˜ƒdealer๎˜ƒshould๎˜ƒbe๎˜ƒable๎˜ƒto๎˜ƒassist๎˜ƒyou.๎˜ƒ๎˜ƒYou ๎˜ƒcan
๎˜ƒalso๎˜ƒlook๎˜ƒat๎˜ƒour๎˜ƒwebsite๎˜ƒfor๎˜ƒsome๎˜ƒadditional๎˜ƒinformation๎˜ƒand๎˜ƒcontact๎˜ƒ
information๎˜ƒfor๎˜ƒtechnical๎˜ƒsupport.๎˜ƒ
๎˜ƒ
Once๎˜ƒyour๎˜ƒpress๎˜ƒthe๎˜ƒON/OFF๎˜ƒbutton๎˜ƒon๎˜ƒyour๎˜ƒstove,๎˜ƒthe๎˜ƒcombustion๎˜ƒfan๎˜ƒwill๎˜ƒstart๎˜ƒimmediately๎˜ƒand๎˜ƒthe๎˜ƒunit๎˜ƒwill๎˜ƒgo๎˜ƒinto๎˜ƒa๎˜ƒpreโ€
programmed๎˜ƒstartโ€up๎˜ƒcycle.๎˜ƒ
STARTโ€UP๎˜ƒCYCLE๎˜ƒ
When๎˜ƒthe๎˜ƒunit๎˜ƒis๎˜ƒfirst
๎˜ƒstarted,๎˜ƒor๎˜ƒwhen๎˜ƒrestarting๎˜ƒafter๎˜ƒthe๎˜ƒpower๎˜ƒhas๎˜ƒbeen๎˜ƒinterrupted,๎˜ƒit๎˜ƒwill๎˜ƒinitially๎˜ƒbe๎˜ƒin๎˜ƒa๎˜ƒpreโ€programmed๎˜ƒstartโ€
up๎˜ƒcycle.๎˜ƒ๎˜ƒThis๎˜ƒstartโ€up๎˜ƒcycle๎˜ƒwill๎˜ƒlast๎˜ƒseven๎˜ƒminutes.๎˜ƒ๎˜ƒDuring๎˜ƒthis๎˜ƒperiod๎˜ƒthe๎˜ƒstove๎˜ƒwill๎˜ƒnot๎˜ƒfunction๎˜ƒon๎˜ƒthe๎˜ƒheat๎˜ƒlevel๎˜ƒsetting๎˜ƒyou๎˜ƒhave๎˜ƒ
selected.๎˜ƒ๎˜ƒInstead,๎˜ƒthe๎˜ƒunit๎˜ƒwill๎˜ƒfunction๎˜ƒ
at๎˜ƒlow๎˜ƒheat๎˜ƒlevel๎˜ƒsetting๎˜ƒ(#1)๎˜ƒuntil๎˜ƒthe๎˜ƒstartโ€up๎˜ƒcycle๎˜ƒis๎˜ƒcompleted.๎˜ƒ๎˜ƒ
๎˜ƒ
Once๎˜ƒthe๎˜ƒstove๎˜ƒhas๎˜ƒreached๎˜ƒthe๎˜ƒminimum๎˜ƒoperating๎˜ƒtemperature,๎˜ƒthe๎˜ƒconvection๎˜ƒblower๎˜ƒwill๎˜ƒcome๎˜ƒon๎˜ƒand๎˜ƒbegin๎˜ƒto๎˜ƒblow๎˜ƒair๎˜ƒinto๎˜ƒthe๎˜ƒ
room.๎˜ƒ๎˜ƒA๎˜ƒshort๎˜ƒtime๎˜ƒlater,๎˜ƒthe๎˜ƒunit๎˜ƒwill๎˜ƒcomplete๎˜ƒthe๎˜ƒstartโ€up๎˜ƒcycle๎˜ƒand๎˜ƒthe๎˜ƒunit
๎˜ƒwill๎˜ƒadvance๎˜ƒto๎˜ƒthe๎˜ƒheat๎˜ƒlevel๎˜ƒsetting๎˜ƒyou๎˜ƒhave๎˜ƒthe๎˜ƒ
stove๎˜ƒset๎˜ƒto.๎˜ƒ
CHANGING๎˜ƒHEAT๎˜ƒLEVELS๎˜ƒ
When๎˜ƒadjusting๎˜ƒthe๎˜ƒheat๎˜ƒlevel๎˜ƒsetting,๎˜ƒkeep๎˜ƒin๎˜ƒmind๎˜ƒthat๎˜ƒyou๎˜ƒwill๎˜ƒexperience๎˜ƒan๎˜ƒapproximate๎˜ƒ3๎˜ƒminute๎˜ƒdelay๎˜ƒbetween๎˜ƒsuccessive๎˜ƒ
heat๎˜ƒlevel๎˜ƒincreases.๎˜ƒ๎˜ƒThis๎˜ƒdelay๎˜ƒis๎˜ƒthere๎˜ƒin๎˜ƒorder๎˜ƒto๎˜ƒallow๎˜ƒthe๎˜ƒfire๎˜ƒto๎˜ƒ
stabilize๎˜ƒbetween๎˜ƒeach๎˜ƒheat๎˜ƒlevel๎˜ƒsetting.๎˜ƒ๎˜ƒThis๎˜ƒdelay๎˜ƒaffects๎˜ƒnot๎˜ƒ
only๎˜ƒthe๎˜ƒauger๎˜ƒfeed๎˜ƒrate,๎˜ƒbut๎˜ƒalso๎˜ƒthe๎˜ƒblower๎˜ƒspeeds.๎˜ƒ
๎˜ƒ
When๎˜ƒthe๎˜ƒHeat๎˜ƒLevel๎˜ƒsetting๎˜ƒis๎˜ƒincreased๎˜ƒor๎˜ƒdecreased,๎˜ƒthe๎˜ƒfuel๎˜ƒfeed๎˜ƒrate,๎˜ƒconvection๎˜ƒfan๎˜ƒspeed๎˜ƒand๎˜ƒcombustion๎˜ƒfan๎˜ƒspeed๎˜ƒare๎˜ƒall๎˜ƒ
affected๎˜ƒafter๎˜ƒthe๎˜ƒ3๎˜ƒminute๎˜ƒbuiltโ€in๎˜ƒdelay.๎˜ƒ
๎˜ƒ
NOTE:๎˜ƒ๎˜ƒW
HENEVER๎˜ƒYOU๎˜ƒCHANGE๎˜ƒTHE๎˜ƒHEAT๎˜ƒLEVEL๎˜ƒSETTING,๎˜ƒIT๎˜ƒIS๎˜ƒALWAYS๎˜ƒA๎˜ƒGOOD๎˜ƒIDEA๎˜ƒTO๎˜ƒOBSERVE๎˜ƒTHE๎˜ƒFIRE๎˜ƒFOR๎˜ƒ10๎˜ƒOR๎˜ƒ15๎˜ƒMINUTES,๎˜ƒAND๎˜ƒTO๎˜ƒADJUST๎˜ƒTHE๎˜ƒ
DAMPER๎˜ƒIF๎˜ƒNEEDED
.๎˜ƒ
๎˜ƒ
DAMPER๎˜ƒCONTROL๎˜ƒ
The๎˜ƒdamper๎˜ƒis๎˜ƒlocated๎˜ƒjust๎˜ƒbeneath๎˜ƒthe๎˜ƒmain๎˜ƒdoor.๎˜ƒ๎˜ƒYou๎˜ƒwill๎˜ƒinitially๎˜ƒadjust๎˜ƒyour๎˜ƒ
damper๎˜ƒfor๎˜ƒthe๎˜ƒbest๎˜ƒperformance๎˜ƒof๎˜ƒyour๎˜ƒstove๎˜ƒdepending๎˜ƒon๎˜ƒyour๎˜ƒoperating๎˜ƒ
heat๎˜ƒlevel,๎˜ƒaltitude,๎˜ƒexhaust๎˜ƒconfiguration,๎˜ƒand๎˜ƒtype๎˜ƒand๎˜ƒquality๎˜ƒof๎˜ƒfuel.๎˜ƒ๎˜ƒAfter๎˜ƒ
that,๎˜ƒyou๎˜ƒshould๎˜ƒnot๎˜ƒneed๎˜ƒto๎˜ƒadjust๎˜ƒthe๎˜ƒdamper๎˜ƒ
on๎˜ƒa๎˜ƒregular๎˜ƒbasis๎˜ƒunless๎˜ƒyou๎˜ƒ
change๎˜ƒthe๎˜ƒheat๎˜ƒlevel.๎˜ƒ
๎˜ƒ
The๎˜ƒcombustion๎˜ƒblower๎˜ƒwill๎˜ƒchange๎˜ƒspeeds๎˜ƒwhen๎˜ƒyou๎˜ƒchange๎˜ƒyour๎˜ƒheat๎˜ƒlevel๎˜ƒ
setting.๎˜ƒ๎˜ƒThis๎˜ƒsubstantially๎˜ƒreduces๎˜ƒthe๎˜ƒneed๎˜ƒfor๎˜ƒdamper๎˜ƒadjustments๎˜ƒso๎˜ƒkeep๎˜ƒin๎˜ƒ
mind๎˜ƒthat๎˜ƒminor๎˜ƒadjustments๎˜ƒto๎˜ƒthe๎˜ƒdamper๎˜ƒcan๎˜ƒhave๎˜ƒa๎˜ƒbig๎˜ƒeffect.๎˜ƒ
๎˜ƒ
When๎˜ƒchanging๎˜ƒfuel๎˜ƒbrands
๎˜ƒor๎˜ƒtype,๎˜ƒclosely๎˜ƒobserve๎˜ƒthe๎˜ƒoperation๎˜ƒof๎˜ƒthe๎˜ƒstove๎˜ƒ
and๎˜ƒmake๎˜ƒadjustments๎˜ƒto๎˜ƒthe๎˜ƒdamper๎˜ƒas๎˜ƒneeded.๎˜ƒ๎˜ƒAlso๎˜ƒmonitor๎˜ƒthe๎˜ƒstove๎˜ƒuntil๎˜ƒ
you๎˜ƒbecome๎˜ƒfamiliar๎˜ƒwith๎˜ƒhow๎˜ƒit๎˜ƒoperates๎˜ƒ
Be๎˜ƒsure๎˜ƒto๎˜ƒuse๎˜ƒthe๎˜ƒmaintenance๎˜ƒtool๎˜ƒprovided๎˜ƒor๎˜ƒa๎˜ƒpair๎˜ƒof๎˜ƒinsulated๎˜ƒfireplace๎˜ƒ
gloves๎˜ƒif๎˜ƒand๎˜ƒwhen๎˜ƒyou๎˜ƒdo๎˜ƒadjust
๎˜ƒthe๎˜ƒdamper.๎˜ƒ
๎˜ƒ
๎˜ƒ
CAUTION:๎˜ƒ๎˜ƒT
HE๎˜ƒDAMPER๎˜ƒCAN๎˜ƒBECOME๎˜ƒHOT๎˜ƒDURING๎˜ƒNORMAL๎˜ƒOPERATION.๎˜ƒ๎˜ƒTO๎˜ƒAVOID๎˜ƒBURNING๎˜ƒYOURSELF,๎˜ƒ
ONLY๎˜ƒADJUST๎˜ƒTHE๎˜ƒDAMPER๎˜ƒWITH๎˜ƒTHE๎˜ƒMAINTENANCE๎˜ƒTOOL
.๎˜ƒ
๎˜ƒ