70
Problems Solution
Temperature reading too
high in the day time
1. Place the sensor in open area and at least 1.5m o the ground.
2. Ensure that the sensor is placed away from heat generating sources or
structures, such as buildings, pavement, walls or air conditioning units.
Some condensation
beneath the UV sensor
may occur overnight
This will disappear when temperature rises up under the sun and will not aect
the performance of the unit.
10. SPECIFICATIONS
10.1 CONSOLE
GENERAL SPECIFICATION
Dimensions (W x H x D) 118 x 192.5 x 21mm (4.6 x 7.6 x 0.8 in) without attach table stand
Weight 269g (with battery)
Main power
DC 5V, 1A adapter
Manufacturer: HUAXU Electronics Factory,
Model: HX075-0501000-AX
Backup battery
CR2032
Operating temperature range -5˚C ~ 50˚C
WI-FI COMMUNICATION SPECIFICATION
Standard 802.11 b/g/n
Operating frequency : 2.4GHz
Supported router security type
WPA/WPA2, WPA3, OPEN, WEP (WEP only support Hexadecimal
password)
Supported device for setup UI
Built-in WI-FI with AP mode function smart devices or laptops e.g.:
Android smart phone, Android pad, iPhone, iPad or PC/Mac computer.
Recommended web browser for
setup UI
Web browsers that support HTML 5, such as the latest version of
Chrome, Safari, Edge, Firefox or Opera.
ONLINE PLATFORM
Website https://proweatherlive.net
App name ProWeatherLive
App platform Google play and Apple Store
WIRELESS SENSOR SIDE COMMUNICATION SPECIFICATION
Support sensors
- 1 Wireless 7-IN-1 weather outdoor sensor
- Up to 7 Wireless hygro-thermo sensors / soil moisture sensor
/ pool sensor (optional)
- Up to 7 Wireless water leak sensors (optional)
RF frequency 868Mhz (EU or UK version)
RF transmission range 150m
TIME RELATED FUNCTION SPECIFICATION
Time display HH: MM
Hour format 12hr AM / PM or 24 hr
Date display DD / MM or MM / DD
Time synchronize method Through PWL to get the local time of the console location
Weekday languages EN / DE / FR / ES / IT / NL / RU
BAROMETER (NOTE: DATA DETECTED BY CONSOLE)
Barometer unit hPa, inHg and mmHg
Measuring range 540 ~ 1100hPa