11 - TROUBLESHOOTING
11-1
All adjustments and repairs shall be made by an authorized Broaster Company representative.
ELECTRICAL TIPS
COMPLAINT CAUSE REMEDY
Probe Fault
1. Open probe circuit
2. Probe wires reversed
3. Probe changes more than
100°F in two seconds.
1. Replace Probe
2. Correct wiring
3. Turn power switch OFF.
Contact service person.
HI Temperature
Oil Temperature has reached
415°F/213°C.
1.Turn power switch OFF.
Contact service person.
Internal Fault
An internal fault has been dis-
covered in the control.
1.Turn power switch OFF.
Contact service person.
Heater Fault - appears if
the oil temperature is less
than 250°F/121°C and the
temperature does not raise
at least 6°F/4°C during any
6 minute time period.
1. Gas valve switch is off.
2. No gas present.
3. Oil Temperature not rising
properly.
1. Turn gas valve switch on.
2. Turn main gas valve on.
3. Turn power switch OFF.
Contact service person.
C1 Fault (Electric Fryers)
This will appear if power is
present at the output of C1
contactor after one second
when the power is turned off.
1.Turn power switch OFF.
Contact service person.