13 - TROUBLESHOOTING
13-1
All adjustments and repairs shall be made by an authorized Broaster Company representative.
ELECTRICAL TIPS
COMPLAINT CAUSE REMEDY
POWER light not illumi-
nated
1. Unit OFF
2. Main power OFF
3. Unplugged
4. Fire extinguisher pressure
below low limit
1. Press ON button
2. Turn ON
3. Plug in
4. Disconnect main power
Contact certified fire sup-
pression agent
Cycle will not start
1. Unit OFF
2. Main power OFF
3. Solid state controller in
program mode
4. Lockout Condition
tripped
5. Platform not lowered
1. Press ON button
2. Turn ON
3. Exit program mode
4. See INDICATOR LIGHTS
below
5. Motor control failure
Contact service person
HEAT ON light not illumi-
nated
1. Unit OFF
2. Main power OFF
3. Solid state controller in
program mode
4. Oil temperature has
reached programmed
temperature
1. Press ON button
2. Turn ON
3. Exit program mode
4. Unit ready to cook
Cycle stops in progress
1. STOP button was pushed
2. Lockout Condition
tripped
1. Press START button
2. See INDICATOR LIGHTS
below
Power Light illuminated but
no power to controller dis-
play
1. Lockout Condition
tripped
1. See INDICATOR LIGHTS
below
broaster.com Manual #16421 5/06 Rev 4/14