5-6
Confidential
1.3
Details of Maintenance Mode Functions for LCD Models
1.3.1 Initialize EEPROM parameters (Function code 01, 91)
<Function>
This function is used to initialize the setting values for operation parameters, user switches,
and worker switches (WSW) registered in the EEPROM.
Entering function code 01 initializes most EEPROM areas. Entering function code 91
initializes only the specified areas as shown in the table below.
<Operating Procedure>
(1) Press the [] or [] in the initial state of maintenance mode to display “Maintenance 01”
(or “Maintenance 91” as required) on the LCD, and press the [OK].
“PARAMETER INIT” is displayed on the LCD.
(2) When initializing parameters is completed, the machine returns to the initial state of
maintenance mode.
Data item 01 91
Printer switch
(Counter information)
Areas not to be
initialized
Areas not to be
initialized
Error history
Mac Address (Ethernet Address)
Continuity counter
Password for control panel operation lock Areas to be
initialized
Secure function lock
Worker switches
User switches (items initialized when
“Factory Reset” is executed)
Areas to be
initialized
Function settings except user switches
(settings not subject to “Factory Reset”)
- Language
- Interface
LAN setting
PCL core area
(Emulation setting values)
Note:
Function code 01 is for service personnel. Function code 91 is for user support.