6-11
Confidential
1.2 Setting by Country (Maintenance Mode: Code 74)
Make appropriate settings by country in accordance with “1.4.23 Setting by country” in Chapter 7.
1.3 Initialization of EEPROM of Main PCB (Maintenance
Mode: Code 01)
Initialize the EEPROM in accordance with “1.4.1 EEPROM parameter initialization” in Chapter 7.
1.4 Setting the Serial Number
<Procedures>
(1) Check that the machine is in the initial state of the maintenance mode, connect the
computer to the machine with the USB cable.
(2) Double-click the “brmainte.exe” file (maintenance utility) which has been copied in the
temporary folder to start.
(3) Select “Input information” from Menu.
(4) Select the applicable model name.
(5) Check the port (USB) that the machine is connected through.
(6) Click “Serial No.” in the lower box. Enter the serial number (the last nine digits) of the
machine into the box on the right hand side and click the OK button.
A confirmation window opens and shows the serial number. Check that it is correct and
click the OK button.
Memo:
Refer to APPENDIX. 3 to know how to read the serial number of the machine.